Vindicator® Optical Control System

Functional Specifications
Operating Wavelength 1550 nm
Wind Speed Range 0 – 38 m/s
Sensing Range Up to 200 meters
Number of Range Gates 3
Range Gate Depth ± 15 meters
Wind Speed Accuracy* ± 0.5 m/s
Wind Direction Accuracy* ±1°
Data Output Rate 1 Hz**
Data Output Format TCP/IP Modbus Over Ethernet***
Internal Data Storage 3 months
Eye-Safety Class 1 (IEC/EN 60825-1)
System Dimensions
Remote Laser Unit 30"L x 19"D
Power & Connectivity Unit 17.5"L x 16"W x 10.5"H
System Weight
Remote Laser Unit 65 lbs.
Power & Connectivity Unit 50 lbs.
System Power
Input Power 110VAC (60Hz)
230VAC (50/60Hz)
Power Consumption 0°C to 55° C: 120W max.
-40°C to 0°C: 600W max.
Environmental Specifications
Operating Temperature -40° to 55°C (-40° to 130°F)
Storage Temperature -40° to 85°C (-40° to 185°F)
*Dependent upon atmospheric conditions **Optional 10 Hz data output rate available ***CANbus/CANopen available upon request